Les Cotton Pumps Ltd.

PWM descriptionInverters intro.

Return to Home Page

PWM Water Control System—details

Energy saving

Test performed with a 1.1 kW electropump and prevalence set to 30 mH2O
Flow
(l/min)
Statistic use of flow Consumption with direct insertion (kW) Consumption with PWM (kW) Power difference (kW) Energy saved in one year (8760 hours) (kW-h)
5 20% 1.295 0.185 1.110 1,945
10 40% 1.388 0.555 0.833 2,917
20 20% 1.480 0.740 0.740 1,296
40 9% 1.573 1.110 0.463 365
70 6% 1.794 1.570 0.224 118
100 5% 1.850 1.850 1.000 0
Total yearly saving (kW-h) 6.641

 

Models

Model PWM 230 1-Basic/4.3 PWM 230 1-Basic/8.5 PWM 230 3-Basic/4.5 PWM 230 D/9.3 PWM 400 D/7.5 PWM 400 D/13.3
Power supply 1 phase x 220 V 3 phase x 380 V
Pump motor type 1 phase × 220 V 3 phase × 220 V 3 phase x 380 V
Max. current 4.3 A rms 8.5 A rms 4.5 A rms 9.3 A rms 7.5 A rms 13.3 A rms
Motor power (approx.) 0.55 kW 1.1 kW 1 kW 2.2 kW 3 kW 5.5 kW
Installation position Any Any Any Any Vertical flow Vertical flow
Max. temperature 50° 50° 50° 45° 45° 45°
Max. pressure 8 bar 16 bar 16 bar 16 bar 16 bar 16 bar
Set pressure range 1—3.6 bar 1—6 bar 1—9 bar 1—15 bar 1—15 bar 1—15 bar
Hydraulic joint inlet 1¼" male 1¼" male 1¼" male 1¼" male 1¼" male 1¼" male
Hydraulic joint outlet 1½" female 1½" female 1½" female 1½" female 1½" female 1½" female
Protection degree IP55 IP55 IP55 IP55 IP55 IP55
Output relay (potential free contact) No 2 (fault; pump running)
Set point 1 2
Digital input (optocoupled) No 1: Float switch
2: Select for 2nd set point
3: Enable
Connectivity No Serial interface RS485
Protection Dry running
Over current
Over temperature
Dry running
Over current
Over temperature
Voltage drop

PWM description

For more information, contact Les Cotton Pumps Ltd:

Email: 
International U.K. Local Rate
Tel: +44 1395 519664 Tel: 0845 458 2892
FAX: +44 1395 516261 Tel: 0845 458 2903
Mail: Les Cotton Pumps Ltd., 5 Bennetts Hill, Sidmouth, Devon, EX10 9XH, U.K.

 

Return to Home PageTop of Page